Product Description

CO2 Monitor

SPECIAL FEATURES

1

Cost-Effective CO2 monitors made with IR-SOC technology

2

NDIR technology to Improve the long term Stability

3

The Alarm mode will sound at 1000PPM or adjust Alarm level

4

Several Modes for adjusting the setting parameters

5

Portable, accurate handheld CO2 Monitor

Specification

Method:

NDIR

Display:

LCD

Independent CO2 and Temperature Readings Calculates Displays Ventilation Rates

Sample Method:

Diffusion or flow through (50-200ml/min)

Performance –CO2 Channel

Flow rate

ZG 106

ZG 106A-M

Measurement Range

0-3000ppm

0-10000ppm

Resolution

1ppm at 0-1000ppm

5ppm at 0-2000ppm

10ppm at 0-3000ppm

1ppm at 0-1000ppm

5ppm at 1001-2000ppm

10ppm at 2001-4000ppm

20ppm at 4001-6000ppm

40ppm at 6001-10,000ppm


Accuracy:

±50ppm or ±5% of Reading

Repeatability:

±20ppm

Temperature Dependence:

±0.1% of Reading per °C or ±2ppm per °C Whichever is greater, referenced to 25°C

Pressure Dependence:

0.13% of Reading per mm Hg(Corrected via user input for attitude)

Response Time:

< 2min for 63%of Step Change

Warm-up time:

<60 Seconds at 22°C

Response time:

< 2min for 63%of Step Change

Performance –Temperature Channel

Temperature Range:

Display 32 to 122 °F (0 to 50 °C)

Display resolution:

0.1°F (0.1°C)

Display Options:

°C/°F or Off . Set up with Up/Down button

Accuracy:

±2°F (±0.1°F)/td>

Response Time:

20-30 minutes

Calibration Interval:

12 Months

Outputs

OC- Normally Low, 100mA max.@24 VDC.Adjustable set point

Factory setting is 1000 ppm

One RJ-45 Connector Digital output in R11 protocal

One graphing Software ZyAura view (Under Developing)

Power Supply

Two Power Supply types

Battery type: Alkaline, AA * 4 (80 Hours)

External: 6 VDC from External AC/DC adapter

Which included in package (Use specified AC adapter only)

Power Requirement

160mA Peak, 15mA average from 6V

General Operating Conditions

Operating Temperature:

32-122 °F (0-50 °C), 0-95% RH, non-condensing

Storage Temperature:

-4 to 140°F (-20 to 60°C)




E-41, Okhla Industrial Area, Phase-II, New Delhi - 110020, India